Browse all practice questions for the CBSPD Tech Certification Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

CBSPD Tech Certification Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What is the major reason acrylic nails are not permitted in the sterile processing department?
  • The purpose of the dynamic air removal cycle of a pre-vacuum steam sterilizer is to
  • Hair coverings are required in all areas of the department to prevent contamination.
  • Safety Data Sheets (SDS) provide health and safety hazard and risk information on which of the following?
  • What does 'dwell time' mean in chemical sterilants?
  • In a sterile processing program, high-level disinfection for semi-critical items is aimed at what outcome?
  • What is the difference between chemical indicators and biological indicators?
  • When heat is added to steam without increasing the moisture content, the steam is called
  • What is load verification?
  • Which chemical indicator should only be used in the specific cycle for which they are labeled?
  • How does a chemical vapor sterilizer operate?
  • Clamps used for hemostasis are designed to achieve which of the following?
  • Which item is an example of a noncritical medical device?
  • A positive biological indicator (BI) test shows that sterilization did not achieve the death of all test organisms. Which option best reflects this result?
  • How should damp loads be handled after sterilization?
  • What is hydrogen peroxide gas plasma sterilization best used for?
  • What is instrument passivation and why is it done?
  • Which type of indicator is placed on the exterior of the packaging to indicate exposure to the cycle?
  • Which statement best describes gravity steam sterilization's effectiveness for complex loads?
  • When a staff member brings contaminated trays to the Sterile Processing Department in a cart and requests replacement trays on the same cart, the technician should:
  • When using the sequential wrapping method
  • Hydrogen peroxide gas plasma sterilization is best described as being suitable for which devices?
  • What is the risk of overloading a steam sterilizer?
  • What is the recommended step after removing contaminated trays from a cart before reloading with clean trays?
  • In mixed loads, the standard arrangement places metal items
  • Surgical grade instruments, if properly cared for, usually last longer than floor grade instruments because they have
  • What is a 'flash' or immediately usable sterilization cycle?
  • A steam sterilizer has two pressure gauges. What pressures do they monitor?
  • The growth of pathogenic bacteria in living tissue is called:
  • What is the purpose of rotating stock using FIFO in sterile storage?
  • What is the best procedure when you are delivering sterile supplies and asked to take an opened/used tray to decontamination?
  • Why are outside shipping cartons often restricted from entering the sterile processing area?
  • To kill the remaining microoragnisms on surgical instruments, the MOST cost-effective sterilization method is generally considered to be
  • What is the primary purpose of a biological indicator in sterilization processes?
  • Which item is least essential for traceability documentation?
  • What is instrument set assembly?
  • In which distribution system are requisitions filled and delivered as they are received?
  • Which agency would approve the disinfectants used on floors and walls in the Sterile Processing Department?
  • Sterility maintenance covers should be placed on sterile items
  • What best describes the general environmental conditions of the sterile storage area?
  • If the operating room requests instruments for an emergency ruptured aortic aneurysm, the technician should send
  • What is the primary difference between disinfection and sterilization?
  • petrolatum gauze sterilization should use which method?
  • Nosocomial infections can be prevented by all the following EXCEPT:
  • An infection acquired due to an improperly sterilized surgical instrument is best categorized as which type of infection?
  • A broken glass suction bottle is returned to Decontamination. What should the technician do?
  • Patient care equipment is considered what level of infection risk?
  • A positive BI result indicates what about the sterilization process?
  • Coronary artery bypass surgery may be performed on patients with which condition?
  • If a technician's skin is exposed to liquid ethylene oxide, what should the technician do FIRST?
  • Which statement best describes the responsibility of load packaging integrity in sterilization?
  • Which statement best describes a 'flash' or immediately usable sterilization cycle?
  • Name three types of chemical indicators used in sterilization packaging.
  • An instrument tray for a laparotomy procedure must include which item?
  • Every healthcare facility has an organizational structure, or chart, that outlines
  • In sterilization records, what does a lot control number primarily enable?
  • During an emergent ruptured aneurysm scenario, which category of instruments is prioritized for preparation?
  • Chemical indicators should be used in the cycle for which they are labeled to ensure which of the following?
  • The MOST commonly recognized halogen is
  • Which of the following is necessary to attain the high temperature needed in a steam sterilizer?
  • For QA and patient safety, which process is essential in sterile processing?
  • The effectiveness of any chemical disinfection process depends on all of the following EXCEPT which?
  • What is the primary reason items should be cooled on a sterilizer cart before storage?
  • Which of the following is NOT classified as a critical medical device?
  • Hair coverings are REQUIRED
  • Which of the following infections is commonly monitored as an occupational hazard in healthcare workers?
  • Which area is used for assembling instrument sets after decontamination?
  • What is wrap compatibility?
  • Which indicator is placed inside the pack to verify interior exposure to the cycle?
  • Failure to completely dry devices before processing in low-temperature gas plasma can result in which outcome?
  • A tray of instruments has been brought to the decontamination area in a saline solution. Which of the following actions should the technician take?
  • Which action demonstrates proper handling of a used tray that must be decontaminated later, during deliveries of sterile supplies?
  • Which factor does NOT influence the effectiveness of chemical disinfection?
  • In the decontamination area, which practice is most effective at preventing cross-contamination?
  • What is the purpose of a Bowie-Dick test?
  • Inspection and verification of adequate cleaning is particularly difficult with instruments that have which feature?
  • What is the difference between wrap materials and rigid containers in packaging for sterilization?
  • If the person maintaining the washer/sterilizer did not remove barrier attire before leaving the area to get more tools, what should the technician do?
  • Paper-plastic pouches are generally used to package
  • In load processing, what is the function of a biological indicator envelope?
  • Heat sensing thermometers in steam sterilizers are located in the
  • Which PPE item is NOT required when manually cleaning devices?
  • What is the primary goal of decontamination procedures in the reprocessing of medical devices?
  • Which sterilization method uses saturated steam under pressure and is most common for wrapped instruments?
  • Simultaneous wrapping means to wrap an instrument set with which configuration?
  • How often should BI results be documented and reviewed?
  • What should you do with a personal text message received during instrument set assembly?
  • The sequential wrapping method involves using how many wrappers in sequence?
  • Why is instrument tracking important?
  • What is the best method to reprocess patient care equipment?
  • Which condition is most characteristic of the sterile storage area's environment?
  • Which statement best describes sterility maintenance covers usage?
  • After manually cleaning contaminated surgical instruments, the NEXT step in the decontamination process is
  • Which statement best describes a reusable barrier system in packaging?
  • Which solution is generally considered MOST appropriate for high level disinfection of semi-critical devices?
  • When working the decontamination area, transmission of pathogenic organisms from used surgical instruments can BEST be minimized by
  • What is the role of a chemical integrator in sterilization packaging?
  • A spore test result showing growth indicates that the sterilization cycle did not achieve sterility.
  • To whom should you report a barrier attire breach in the decontamination area?
  • For high-level disinfection of semi-critical devices, which concentration is commonly used?
  • Semi-critical items contact mucous membranes and require what level of processing?
  • What is the role of quality control in sterilization?
  • Name two primary categories of indicators used in sterilization validation.
  • What is the purpose of a biological indicator envelope in load processing?
  • The dynamic air removal cycle is a feature of which sterilization system?
  • If you forget to punch your time card, what is the appropriate reporting action?
  • Which statement about low-temperature gas plasma processing is true regarding drying?
  • The pH of the detergent solution demonstrated to be safest for cleaning surgical instruments is which level?
  • Lot control numbers are used to
  • When a steam sterilizer load contains a mixture of fabric and metal items, the items should be placed
  • Generally, the first step in loosening blood soils from the channels of an instrument is to soak it in
  • Which data is essential to record for every sterilization load to support traceability?
  • When is residual testing required for sterilization methods like ethylene oxide (EO)?
  • In the standard workflow, which area comes immediately after Assembly?
  • Which item is specifically associated with a laparotomy instrument tray to ensure access to the surgical field?
  • What is the correct action when you observe dressing supplies being used for personal purposes?
  • When preparing a set of instruments for processing in a washer/decontaminator, how should the instruments be positioned inside the basket?
  • Which statement about quality control in sterilization is most accurate?
  • What is the primary method for reducing microbial load on reprocessed devices to enable sterilization?
  • When using ethylene oxide (EO) sterilization, what is a critical safety requirement?
  • The Bowie-Dick test is designed to be performed in which sterilizer type?
  • Which items are considered 'critical' in sterile processing?
  • Load verification uses which indicators?
  • In steam sterilization, containerized packaging systems primarily protect instrument sets from which of the following during handling?
  • Why is it important to follow the equipment manufacturer's instructions during reprocessing?
  • What is load integrity?
  • What is the recommended practice regarding reprocessing single-use devices?
  • To ensure sterility after damp loads, which action is appropriate?
  • How should sterile packaged items be transported by hand?
  • Which factor is described as the most important in preventing contamination of sterile packages?
  • When is gravity displacement steam sterilization preferred over prevacuum?
  • Heat sensing thermometers for steam sterilizers are located in the
  • When transporting sterile instruments, what is the key principle to prevent contamination?
  • What are the major physical areas of a typical Sterile Processing Department?
  • "Clean to dirty" is a sterile processing department term used to describe
  • When a steam sterilizer is loaded with linen packs, they should be
  • What is Bowie-Dick testing used for?
  • Which organization sets standards commonly referenced in sterile processing?
  • Which statement accurately describes patient care equipment in terms of infection control risk?
  • What is meant by "dry time" in a sterilization cycle?
  • The chemical disinfectant that leaves a residual film is
  • What are OSHA obligations relevant to sterile processing?
  • What does traceability mean in sterile processing?
  • The most important factor in preventing bacteria from contaminating sterile packages is
  • What is the purpose of instrument wrap materials?
  • What is the difference between prevacuum and gravity steam sterilization cycles?
  • What is load configuration in sterilization?
  • Containerized packaging systems are most commonly used to protect which during steam sterilization?
  • Which category of medical devices requires sterilization before use due to penetrating the body or contacting sterile tissues?
  • How should single-use devices be handled if found in decontamination?
  • Where should lot control numbers be placed?
  • A surgical grade instrument set lasts longer because it includes a passivation layer that provides corrosion resistance.
  • If hair is visible outside the surgical cap during set assembly, what action is appropriate?
  • If you forget to punch your time card and you are leaving soon, what action should you take?
  • What is a spore test used for?
  • Which description BEST describes the manual cleaning process of surgical instruments?
  • After BI results are documented, what action is required if the results indicate a problem?
  • You receive a cell phone text message while assembling instrument sets. Which action is BEST to take?
  • Which additional indicators function as supporting indicators along with chemical and biological indicators?
  • Which area is primarily used for receiving contaminated items from patient care areas?
  • Which statement describes the purpose of dry time?
  • Humidity in steam sterilization cycles is considered where applicable.
  • Which of the following is the main DISADVANTAGE of using a rigid sterilization container system?
  • When cleaning an intravenous (IV) pump, it is important to use a germicide on the pump surface in order to
  • Which statement about critical items is accurate?
  • Cotton gauze cannot be used in which sterilization process?
  • Which statement is true regarding periodic maintenance on sterilizers?
  • What is the primary purpose of soaking instruments in an enzymatic detergent before cleaning?
  • What is the purpose of a final rinse in cleaning or decontamination?
  • Which sequence best describes the traffic workflow in areas where medical devices are processed?
  • Which statement best describes sterile storage best practices?
  • Which area is used for storing sterile items after they have been sterilized?
  • Basin sets on the steam sterilizer rack should be oriented to permit condensate to run off. Which description best fits the recommended orientation?
  • FIRST action when you see a coworker taking dressing supplies for home use?
  • Healthcare workers are most likely to be infected by which of the following agents?
  • The function of the gastrointestinal system is to which?
  • In an emergency situation where a used IV pump is urgently needed, what is the ethically correct action?
  • Outside shipping cartons should not be brought into sterile processing area because they are often
  • What practical drawback is associated with using rigid sterilization containers in routine operation room sterilization workflows?
  • Why is instrument count verification important after processing?
  • A liver biopsy is performed to check for which disease?
  • What is the typical validated parameter set for a gravity displacement steam sterilization cycle?
  • Loose fitting clothing and jewelry should NOT be worn in sterile processing because it
  • What is the purpose of air removal in autoclaves?
  • Instrument passivation is primarily designed to:
  • What should be done if a BI result is invalid or does not grow?
  • When there is an emergency admission and equipment is needed, what is the most appropriate course of action?
  • Which combination of indicators is used for load verification?
  • All of the following agencies regulate ethylene oxide as a sterilant EXCEPT
  • In sterilization, what are the three basic parameters that must be controlled and documented?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy